    PLC Programming: Sorting and Distribution of Boxes by Height

       (0 reviews)

    xiangjinjiao

    In this PLC programming, we do sorting and distribution of boxes by height into the designated storage bins using sensors and conveyors.

    This PLC program distributes the specified number of parts according to their size.

    PLC Sorting Boxes by Height

    The below simulation shows the working principle of PLC logic for sorting boxes based on their height. Here we have 3 different size boxes like small, medium, and large sizes.

    There are three storage bins for each box size. There are three pushers and three conveyors. Each box size has one pusher and one conveyor.

    spacer.png

    The robot places the boxes randomly on the conveyor. The sensors are used to detect the box’s size. The conveyors are started and stopped when the respective box size reaches there using the sensors.

    The respective pusher is activated and moves the respective box size to the dedicated storage bins.

    PLC I/O List

    The below table lists the inputs and outputs of this system.

    Type Device No. evice Name Operation
    Input X0 Starting point ON when the robot is at starting point.
    Input X1 Upper ON when the part is detected.
    Input X2 Middle ON when the part is detected.
    Input X3 Lower ON when the part is detected.
    Input X4 Sensor ON when the part is detected on the incline.
    Input X5 Sensor ON when the part is detected on the incline.
    Input X6 Sensor ON when the part is detected on the incline.
    Input X7 Sensor ON when the part is detected at the right end.
    Input X10 Detect part ON when the part is detected in front of the pusher.
    Input X11 Detect part ON when the part is detected in front of the pusher.
    Input X12 Detect part ON when the part is detected in front of the pusher.
    Output Y0 Supply command One part is supplied When Y0 is ON. A process cycle begins: Wooden part repeats in order M, S, L, M, M, L, S, S, L, L.
    Output Y1 Conveyor forward The conveyor moves forward when Y1 is ON.
    Output Y2 Conveyor forward The conveyor moves forward when Y2 is ON.
    Output Y3 Conveyor forward The conveyor moves forward when Y3 is ON.
    Output Y4 Conveyor forward The conveyor moves forward when Y4 is ON.
    Output Y5 Pusher Extends when Y5 is ON and retracts when Y5 is OFF. The pusher cannot be stopped in the mid-stroke.
    Output Y6 Pusher Extends when Y6 is ON and retracts when Y6 is OFF. The pusher cannot be stopped in the mid-stroke.
    Output Y7 Pusher Extends when Y7 is ON and retracts when Y7 is OFF. The pusher cannot be stopped in the mid-stroke.

    Program Description

    Programming a Programmable Logic Controller (PLC) for Box Sorting Based on Height and Component Distribution.

    Initiating the robot’s operation involves pressing the pushbutton PB1 (X20) located on the control panel, which activates the Robot Supply Command (Y0).

    The Robot Supply Command (Y0) is deactivated upon the robot completing the part movement and returning to its initial position.

    The Conveyor Movement Command is controlled by the Switch SW1 (X24) on the control panel. Activating the switch (turning it ON) propels the conveyor’s movement forward while deactivating it (turning it OFF) brings the conveyor to a halt.

    Sorting of parts, segregated into large, medium, and small sizes, is executed through the input from the Upper (X1), Middle (X2), and Lower (X3) sensors. Post-sorting, the parts are conveyed to their designated trays.

    The presence of a part in the pusher is identified by the activation (turning ON) of the Part Detection Sensors (X10, X11, or X12). Upon part detection, the conveyor is brought to a halt, and the detected part is displaced onto the tray.

    Note: The operation of the pusher is governed by the Pusher Actuation Command. Upon receiving an ON signal, the pusher fully extends, while an OFF signal causes the pusher to retract.

    Each tray is to contain a specific number of parts, depending on their size. Any parts exceeding these specified numbers bypass the pusher and are ejected from the conveyor at the right end.

    The designated number of parts per size is as follows:

    • Large: 3 parts
    • Medium: 2 parts
    • Small: 2 parts

    PLC Ladder Logic

    121-2.gif121-3.gif

    Sign in to follow this  


    User Feedback

    Recommended Comments

    There are no comments to display.



    Create an account or sign in to comment

    You need to be a member in order to leave a comment

    Create an account

    Sign up for a new account in our community. It's easy!

    Register a new account

    Sign in

    Already have an account? Sign in here.

    Sign In Now

Apply for friendship links:WhatsApp or E-mail: admin@plchmis.com
×
×
  • Create New...